MIR-Waveguide / MIRa-Guide

ATR-single-mode-waveguide for spectroscopy of solids and liquids in the mid infrared range (MIR)

Absorption Spectroscopy

MIRa-Guide – Advanced mid-infrared waveguide technology for analyzing solids and liquids

MIRa_Guide Logo

  • Miniaturized thin film ATR set-up
  • Frequency-matched to MIR-Lasers
  • MIRa-lab-on-a-chip possible
  • ACTUAL available for two transmission ranges:
    approx. 1700 to 1250 cm-1 (6-8 μm)                          and 1250 to 900 cm-1 (8-11 μm)

Mid-Infrared single-mode waveguide for spectroscopy of solids and liquids.

MIRa-Guide® is a single-mode waveguide especially designed for the mid-infrared absorption spectroscopy based on tunable IR light sources offering a by an order of magnitude reduced footprint compared to conventional technologies such as Attenuated-Total-Reflection-Cells (ATR-Cell).

Download
Advanced mid-infrared waveguide technology for analyzing solids and liquids
MIRa-Guide® is a single-mode waveguide especially designed for mid-infrared absorption spectroscopy based on tunable IR light sources such as Quantum Cascade Lasers (QCLs), Interband Cascade Lasers (ICLs), and Optical Parametric Oscillators (OPOs).
MGOS_MIRa-Guide _Datenblatt20180504.pdf
Adobe Acrobat Dokument 491.7 KB

Information needed which you can't find? - Contact us, we prefer to maintain a personal relationship with our customers, rather than our website.

 

contact@mgopticalsolutions.com

+49-(0)8806 534 3255

We give our best to support you.



Reference List of relevant publications

 

Chem Soc Rev

REVIEW ARTICLE

 

Waveguide-enhanced mid-infrared chem/bio sensors
Boris Mizaikoff

 

 

Analytical Methods                           

 

Sensing Chlorinated Hydrocarbons via Miniaturized GaAs/AlGaAs Thin-Film Waveguide Flow Cells Coupled to Quantum Cascade Lasers
Julian Haas(a), Robert Stach(a), Markus Sieger(a), Zana Gashi(a), Matthias Godejohann(b), and Boris Mizaikoff(a)

     a)    Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany

     b)    MG Optical Solutions GmbH, Industriestr. 23, 86919 Utting/Ammersee, Germany

 

 

analytical chemistry                         

 

Mid-Infrared Spectroscopy Platform Based on GaAs/AlGaAs Thin-Film Waveguides and Quantum Cascade Lasers

Markus Sieger, Julian Haas, Michael Jetter, Peter Michler, Matthias Godejohann,§ and Boris Mizaikoff,

  Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany

  Institut für Halbleiteroptik und Funktionelle Grenzflächen, Universität Stuttgart, Allmandring 3, 70565 Stuttgart, Germany

 § MG Optical Solutions GmbH, Industriestr. 23, 86919 Utting/Ammersee, Germany

 

 

analytical chemistry                         

 

Toward On-Chip Mid-Infrared Sensors     

Markus Sieger and Boris Mizaikoff

Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany

 

 

analytical chemistry                         

 

On-Chip Integrated Mid-Infrared GaAs/AlGaAs MachZehnder Interferometer

Markus Sieger Markus Sieger, Franz Balluff, Xiaofeng Wang, Seong-Soo Kim, Lothar Leidner, Guenter Gauglitz, and Boris Mizaikoff*,

  Institute of Analytical and Bioanalytical Chemistry, University of Ulm, Albert-Einstein-Allee 11, 89075 Ulm, Germany

  Institute of Theoretical and Physical Chemistry, University of Tuebingen, Auf der Morgenstelle 15, 72076 Tuebingen, Germany