NLIR

Nonlinear Infrared Sensors

NLIR is a start-up company founded by 3 researchers at the Department of Photonics Engineering at the Technical University of Denmark (DTU Fotonik) and NLIR’s CEO. NLIR is based on the novel patented upconversion technology invented by its founders at DTU Fotonik.

The core of the upconversion technology is a non-linear crystal that converts mid infrared light to near visible light. This enables the use of fast and efficient Silicon based sensors for detection of MIR light.

The non-linear mid infrared spectrometer implementation represents a revolutionary new measurement paradigm. The company is named Non-Linear InfraRed sensors (NLIR) to highlight the products technological difference from todays leading MIR spectrometry method of Fourier-Transform InfraRed spectroscopy (FTIR).

NLIR target at several industry sectors: Oil and gas, Polymer, Food and Agriculture, Pharmaceutical, Chemical, Medical Diagnostic and Environmental.


MIR Spectrometers


NLIR_S2055_MIR_Spectrometer

The NLIR S2055 spectrometer covers a broad part of the MIR spectrum where the spectral fingerprints of many C-H bonds of gases are located together with those of a number of other common gases. Many plastics (independent of color) also absorb in this MIR region, which makes indentification easily accessible

  • Broadband operation from 2.0 - 5.5 µm /1818-5000 cm-1
  • Entire spectrum in milliseconds
  • Very robust - no moving parts
  • Based on novel upconversion technology

Key applications:

  • Black plastic sorting
  • Gas concentration measurements
  • Polymer identification
  • Petrochemical analysis
  • Broadband IR coating quality control
  • MIR super-continuum light measurements

 

 

Download
Datasheet
NLIR S2055 MIR Spectrometer Datasheet.pd
Adobe Acrobat Dokument 391.0 KB

NLIR_S3055_MIR_Spectrometer

S3055 3.0-5.5µm Spectrometer

The S3055 offers high speed mid infrared spectroscopy with high SNR measurements and a spectral resolution down to 8cm-1. It is a superior alternative to traditional FTIR technologies in applications that require fast operation, high SNR and tolerance to vibrations. Hence covering the requirements for In-Line industrial measurements.

 

Spectral range           3333 - 1818 cm-1

Spectral resolution     8 cm-1

Cooling                     Uncooled

SNR                         @1sup to 20.000

Integration                time~1 ms

Durability                  Vibration tolerant

Dimensions (LxWxH)  260x235x75 mm

 


NLIR_S50125_MIR_Spectrometer

The S50125 prototype offers high speed mid infrared spectroscopy with high SNR measurements and a spectral resolution down to 4cm-1. It is a superior alternative to traditional FTIR technologies in applications that require fast operation, high SNR and tolerance to vibrations. Hence covering the requirements for In-Line industrial measurements.

S50125 5.5-12.5µm Prototype Spectrometer

Spectral Range          5.0 - 12.5 μm/ 800 - 2000 cm-1

SNR @ 1 s                 ~ 4.000 (depending on light source)

Resolution                 Down to 4 cm-1 

Min. exposure time     10.8 µs

Maximum spectrum readout rate  >100 Hz

Optical input              Free space

Connection                Ethernet

Measurement options Transmission, ATR

Bit depth                   16 bit

Dimensions (H×L×W) 90x275×175 mm


Download
Datasheet
NLIR S50125 MIR Spectrometer Prototype D
Adobe Acrobat Dokument 239.4 KB

MIR Detectors


NLIR_D2250_MIR_Detector     MID-Infrared Light Detector

The NLIR MIR light detector is based on a novel measurement scheme that upconverts the MIR light to the near-visible regime. Near-visible light detectors  (based on for example Si) are far superior to MIR light detectors in terms of efficiency, speed and noise.

  • Single-wavelength detection from 2.2 - 5.0 µm
  • DC - 10 GHz bandwith
  • NEP down to 2fW/√Hz
  • Based on novel upconversion technology

Key applications:

  • Nanosecond pulse characterisation
  • Low-power MIR light detection
  • Detection of gas lines
  • Free-space communication
  • DIAL (differential absorption LIDAR)
  • Chemical kinetics

Near-visible light detectors exist with many different combinations of specifications  and what detector to choose depends on the desired application.

 

Download
Datasheet
NLIR D2250 MIR Detector Datasheet.pdf
Adobe Acrobat Dokument 303.8 KB

NLIR-D3055 Detector

 

D3055 3.0-5.5µm Detector

Ultra-sensitive uncooled mid infrared detector. Demonstrated to detect 500 times lower MIR signals than a cryogenic cooled InSb detector.

 

Spectral range          3.0 - 5.5 µm

Sensor                     Silicon photodiode

NEP                         20 fW/sqrt(Hz)

Cooling                    TEC controlled

Sampling                  >0.5 ns

Field of view             25°

Durability                 Vibration tolerant

Dimensions (LxWxH) 260x235x75 mm

 

 


NLIR-D3055C Customized Detector

Our D3055 detector can be custom optimized for speed or sensitivity.

 

 

 

D3055C 3.0-5.5µm Customized Detector

Spectral range          3.0 - 5.5 µm

Sensor                     Custom

NEP                         Custom

Cooling                    Custom

Sampling                 Custom

Field of view             25°

Durability                 Vibration tolerant

Dimensions (LxWxH) 260x235x75 mm